1 change: 1 addition & 0 deletions zhaquirks/stelpro/__init__.py
Original file line number Diff line number Diff line change
@@ -0,0 +1 @@
"""Quirks for Stelpro devices."""
94 changes: 94 additions & 0 deletions zhaquirks/stelpro/allia_ht402.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,94 @@
"""ZHA Quirk (v2) for Stello HT402.

Adds manufacturer attributes:
- 0x4008: Instant power (W)
- 0x4009: Cumulative energy (Wh)
- 0x4001: Outdoor temperature (°C or °F, read/write)
"""

from typing import Final

from zigpy.quirks import CustomCluster
from zigpy.quirks.v2 import (
QuirkBuilder,
ReportingConfig,
SensorDeviceClass,
SensorStateClass,
)
from zigpy.quirks.v2.homeassistant import UnitOfEnergy, UnitOfPower, UnitOfTemperature
import zigpy.types as t
from zigpy.zcl.clusters.hvac import Thermostat
from zigpy.zcl.foundation import ZCLAttributeDef

MANUFACTURER: Final = "Stello"
MODEL: Final = "HT402"
EP_THERMOSTAT: Final = 25 # 0x19


class AlliaThermostatCluster(Thermostat, CustomCluster):
"""Thermostat cluster extended with Stello/Allia manufacturer attributes."""

class AttributeDefs(Thermostat.AttributeDefs):
"""Vendor-specific attributes added to the Thermostat cluster.

- 0x4001: outdoor temperature (°C or °F), int16, read/write
- 0x4008: instant power (W), uint16, read-only
- 0x4009: cumulative energy (Wh), uint32, read-only
"""

# 0x4001: Outdoor temperature (int16, read/write)
allia_outdoor_temperature = ZCLAttributeDef(
id=0x4001,
type=t.int16s,
access="rpw", # readable, reportable, writable
)
# 0x4008: Instant power in Watts (uint16)
allia_power_w = ZCLAttributeDef(id=0x4008, type=t.uint16_t, access="rp")
# 0x4009: Cumulative energy in Watt-hours (uint32)
allia_energy_wh = ZCLAttributeDef(id=0x4009, type=t.uint32_t, access="rp")


(
QuirkBuilder(MANUFACTURER, MODEL)
.replaces(AlliaThermostatCluster, endpoint_id=EP_THERMOSTAT)
# Instant Power
.sensor(
attribute_name=AlliaThermostatCluster.AttributeDefs.allia_power_w.name,
cluster_id=AlliaThermostatCluster.cluster_id,
endpoint_id=EP_THERMOSTAT,
device_class=SensorDeviceClass.POWER,
state_class=SensorStateClass.MEASUREMENT,
unit=UnitOfPower.WATT,
reporting_config=ReportingConfig(
min_interval=5, max_interval=300, reportable_change=1
),
translation_key="allia_power_w",
fallback_name="Allia Power",
)
# Energy (cumulative)
.sensor(
attribute_name=AlliaThermostatCluster.AttributeDefs.allia_energy_wh.name,
cluster_id=AlliaThermostatCluster.cluster_id,
endpoint_id=EP_THERMOSTAT,
device_class=SensorDeviceClass.ENERGY,
state_class=SensorStateClass.TOTAL_INCREASING,
unit=UnitOfEnergy.WATT_HOUR,
reporting_config=ReportingConfig(
min_interval=30, max_interval=3600, reportable_change=10
),
translation_key="allia_energy_wh",
fallback_name="Allia Energy",
)
# Outdoor Temperature (0x4001) — read/write
.sensor(
attribute_name=AlliaThermostatCluster.AttributeDefs.allia_outdoor_temperature.name,
cluster_id=AlliaThermostatCluster.cluster_id,
endpoint_id=EP_THERMOSTAT,
device_class=SensorDeviceClass.TEMPERATURE,
state_class=SensorStateClass.MEASUREMENT,
unit=UnitOfTemperature.CELSIUS, # Would need to convert to F
translation_key="allia_outdoor_temperature",
fallback_name="Outdoor Temperature",
)
.add_to_registry()
)