| 1 | +#include "PDBMonitoring.h" |
| 2 | + |
| 3 | +#include <cmath> |
| 4 | + |
| 5 | +#include "Logger.h" |
| 6 | + |
| 7 | +const float PDBMonitoring::PDB_VBAT_RAIL_NOMINAL_VOLTAGE = 24.0; |
| 8 | +const float PDBMonitoring::PDB_VBAT_RAIL_MIN_THRESHOLD = 18.0; |
| 9 | +const float PDBMonitoring::PDB_VBAT_RAIL_MAX_THRESHOLD = 25.2; |
| 10 | + |
| 11 | +const float PDBMonitoring::PDB_24V_RAIL_NOMINAL_VOLTAGE = 24.0; |
| 12 | +const float PDBMonitoring::PDB_24V_RAIL_MIN_THRESHOLD = 22.0; |
| 13 | +const float PDBMonitoring::PDB_24V_RAIL_MAX_THRESHOLD = 26.0; |
| 14 | + |
| 15 | +const float PDBMonitoring::PDB_17V_RAIL_NOMINAL_VOLTAGE = 17.0; |
| 16 | +const float PDBMonitoring::PDB_17V_RAIL_MIN_THRESHOLD = 16.0; |
| 17 | +const float PDBMonitoring::PDB_17V_RAIL_MAX_THRESHOLD = 18.0; |
| 18 | + |
| 19 | +const float PDBMonitoring::PDB_5V_RAIL_NOMINAL_VOLTAGE = 5.0; |
| 20 | +const float PDBMonitoring::PDB_5V_RAIL_MIN_THRESHOLD = 4.8; |
| 21 | +const float PDBMonitoring::PDB_5V_RAIL_MAX_THRESHOLD = 6.0; |
| 22 | + |
| 23 | +const float PDBMonitoring::PDB_TEMPERATURE_MIN_THRESHOLD = 10.0; |
| 24 | +const float PDBMonitoring::PDB_TEMPERATURE_MAX_THRESHOLD = 50.0; |
| 25 | + |
| 26 | +const bool PDBMonitoring::PDB_5V_LOAD1_DIAG_EN = 1; |
| 27 | +const bool PDBMonitoring::PDB_5V_LOAD2_DIAG_EN = 0; |
| 28 | +const bool PDBMonitoring::PDB_5V_LOAD3_DIAG_EN = 0; |
| 29 | +const bool PDBMonitoring::PDB_5V_LOAD4_DIAG_EN = 0; |
| 30 | +const bool PDBMonitoring::PDB_5V_LOAD5_DIAG_EN = 0; |
| 31 | +const bool PDBMonitoring::PDB_17V_LOAD_DIAG_EN = 1; |
| 32 | + |
| 33 | +PDBMonitoring::PDBMonitoring() |
| 34 | + : load1_5V_diag_en(LOAD1_5V_DIAG_EN), |
| 35 | + load1_5V_fault_n(LOAD1_5V_FAULT), |
| 36 | + load2_5V_diag_en(LOAD2_5V_DIAG_EN), |
| 37 | + load2_5V_fault_n(LOAD2_5V_FAULT), |
| 38 | + load3_5V_diag_en(LOAD3_5V_DIAG_EN), |
| 39 | + load3_5V_fault_n(LOAD3_5V_FAULT), |
| 40 | + load4_5V_diag_en(LOAD4_5V_DIAG_EN), |
| 41 | + load4_5V_fault_n(LOAD4_5V_FAULT), |
| 42 | + load5_5V_diag_en(LOAD5_5V_DIAG_EN), |
| 43 | + load5_5V_fault_n(LOAD5_5V_FAULT), |
| 44 | + load_17V_diag_en(LOAD_17V_DIAG_EN), |
| 45 | + load_17V_fault_n(LOAD_17V_FAULT), |
| 46 | + railBattery(RAIL_BATTERY_ANLG_IN), |
| 47 | + rail5V(RAIL_5V_ANLG_IN), |
| 48 | + rail17V(RAIL_17V_ANLG_IN), |
| 49 | + rail24V(RAIL_24V_ANLG_IN), |
| 50 | + rail24V_pgood_n(RAIL_24V_PGOOD_N), |
| 51 | + temperatureADC(TEMPERATURE_ADC_IN) { |
| 52 | + load1_5V_diag_en = PDB_5V_LOAD1_DIAG_EN; |
| 53 | + load2_5V_diag_en = PDB_5V_LOAD2_DIAG_EN; |
| 54 | + load3_5V_diag_en = PDB_5V_LOAD3_DIAG_EN; |
| 55 | + load4_5V_diag_en = PDB_5V_LOAD4_DIAG_EN; |
| 56 | + load5_5V_diag_en = PDB_5V_LOAD5_DIAG_EN; |
| 57 | + load_17V_diag_en = PDB_17V_LOAD_DIAG_EN; |
| 58 | +} |
| 59 | + |
| 60 | +/*TODO:Replace the logger statements with CAN logs |
| 61 | + * after CAN Module is ready */ |
| 62 | + |
| 63 | +void PDBMonitoring::load_monitoring() { |
| 64 | + if (load1_5V_diag_en && !load1_5V_fault_n) { |
| 65 | + Utility::logger << "Fault on 5V load 1\n"; |
| 66 | + } |
| 67 | + if (load2_5V_diag_en && !load2_5V_fault_n) { |
| 68 | + Utility::logger << "Fault on 5V load 2\n"; |
| 69 | + } |
| 70 | + if (load3_5V_diag_en && !load3_5V_fault_n) { |
| 71 | + Utility::logger << "Fault on 5V load 3\n"; |
| 72 | + } |
| 73 | + if (load4_5V_diag_en && !load4_5V_fault_n) { |
| 74 | + Utility::logger << "Fault on 5V load 4\n"; |
| 75 | + } |
| 76 | + if (load5_5V_diag_en && !load5_5V_fault_n) { |
| 77 | + Utility::logger << "Fault on 5V load 5\n"; |
| 78 | + } |
| 79 | + if (load_17V_diag_en && !load_17V_fault_n) { |
| 80 | + Utility::logger << "Fault on 17V load\n"; |
| 81 | + } |
| 82 | +} |
| 83 | + |
| 84 | +void PDBMonitoring::rail_monitoring() { |
| 85 | + float rail_vbat_voltage = railBattery.read_voltage() / 3 * PDB_VBAT_RAIL_NOMINAL_VOLTAGE; |
| 86 | + float rail_24V_voltage = rail24V.read_voltage() / 3 * PDB_24V_RAIL_NOMINAL_VOLTAGE; |
| 87 | + float rail_17V_voltage = rail17V.read_voltage() / 3 * PDB_17V_RAIL_NOMINAL_VOLTAGE; |
| 88 | + float rail_5V_voltage = rail5V.read_voltage() / 3 * PDB_5V_RAIL_NOMINAL_VOLTAGE; |
| 89 | + |
| 90 | + if (rail_vbat_voltage < PDB_VBAT_RAIL_MIN_THRESHOLD || rail_vbat_voltage > PDB_VBAT_RAIL_MAX_THRESHOLD) { |
| 91 | + Utility::logger << "!!! VBAT RAIL VOLTAGE: %.3fV !!!\n", rail_vbat_voltage; |
| 92 | + } |
| 93 | + if (rail_24V_voltage < PDB_24V_RAIL_MIN_THRESHOLD || rail_24V_voltage > PDB_24V_RAIL_MAX_THRESHOLD) { |
| 94 | + Utility::logger << "!!! 24V RAIL VOLTAGE: %.3fV !!!\n", rail_24V_voltage; |
| 95 | + } |
| 96 | + if (rail_17V_voltage < PDB_17V_RAIL_MIN_THRESHOLD || rail_17V_voltage > PDB_17V_RAIL_MAX_THRESHOLD) { |
| 97 | + Utility::logger << "!!! 17V RAIL VOLTAGE: %.3fV !!!\n", rail_17V_voltage; |
| 98 | + } |
| 99 | + if (rail_5V_voltage < PDB_5V_RAIL_MIN_THRESHOLD || rail_5V_voltage > PDB_5V_RAIL_MAX_THRESHOLD) { |
| 100 | + Utility::logger << "!!! 5V RAIL VOLTAGE: %.3fV !!!\n", rail_5V_voltage; |
| 101 | + } |
| 102 | +} |
| 103 | + |
| 104 | +/*https://www.ti.com/lit/ds/symlink/lmt87-q1.pdf?ts=1627158177761&ref_url=https%253A%252F%252Fwww.google.com%252F*/ |
| 105 | + |
| 106 | +void PDBMonitoring::temperature_monitoring() { |
| 107 | + float temperature_celsius = |
| 108 | + (13.582 - sqrt(pow(-13.582, 2) + 4 * 0.00433 * (2230.8 - temperatureADC.read_voltage() * 1000))) / |
| 109 | + (2 * (-0.00433)) + |
| 110 | + 30; |
| 111 | + |
| 112 | + if (temperature_celsius < PDB_TEMPERATURE_MIN_THRESHOLD || temperature_celsius > PDB_TEMPERATURE_MAX_THRESHOLD) { |
| 113 | + Utility::logger << "!!! TEMPERATURE FAULT:" << temperature_celsius << "degrees Celsius\n"; |
| 114 | + } |
| 115 | +} |
| 116 | + |
| 117 | +void PDBMonitoring::periodic_1s() { |
| 118 | + temperature_monitoring(); |
| 119 | + load_monitoring(); |
| 120 | +} |
| 121 | + |
| 122 | +void PDBMonitoring::periodic_1ms() { |
| 123 | + /*Monitoring Period = 500ms*/ |
| 124 | + int rail_counter = 0; |
| 125 | + |
| 126 | + if (rail_counter % 5 == 0) { |
| 127 | + rail_monitoring(); |
| 128 | + rail_counter = 0; |
| 129 | + } |
| 130 | + |
| 131 | + rail_counter++; |
| 132 | +} |
0 commit comments