Skip to content

Commit e4d7f70

Browse files
committed
Correct issue with calculation.
1 parent ebf0879 commit e4d7f70

File tree

1 file changed

+1
-1
lines changed

1 file changed

+1
-1
lines changed

Source/Orts.Simulation/Simulation/RollingStocks/MSTSSteamLocomotive.cs

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -7476,7 +7476,7 @@ private void UpdateWaterInjection(float elapsedClockSeconds)
74767476
// Temperature Correction Factor = (Tsat - Tfeedwater) / (Tsat - Tref), Assume ref = 20C
74777477

74787478
var ReferenceTemperature = 20.0f; // Reference temperature for injector performance
7479-
ActualInjectorTemperatureCorrectionFactor = ( C.FromF(PressureToTemperaturePSItoF[BoilerPressurePSI]) - TenderWaterTemperatureC) / (C.FromF(PressureToTemperaturePSItoF[BoilerPressurePSI]) - ReferenceTemperature);
7479+
ActualInjectorTemperatureCorrectionFactor = (float)Math.Sqrt(( C.FromF(PressureToTemperaturePSItoF[BoilerPressurePSI]) - TenderWaterTemperatureC) / (C.FromF(PressureToTemperaturePSItoF[BoilerPressurePSI]) - ReferenceTemperature));
74807480

74817481
// Calculate enthalpy of injector feed water based on boiler water temperature
74827482
// hfg kJ/kg) = 2500 - 2.4 * Tsat (C) - 4% accurate, to be explored later for better accuracy

0 commit comments