@@ -30,7 +30,8 @@ Change settings of your Arduino-based Modbus RTU to Modbus TCP/UDP gateway via w
30
30
- send Modbus request and recieve Modbus response
31
31
- scan Modbus slaves on RS485 interface
32
32
- queue (buffer) status
33
-
- error counters (stored in EEPROM)
33
+
- counters ("RTU Data", "Ethernet Data", "Modbus Statistics") are periodically saved to EEPROM (every 6 hours)
34
+
- unsigned longs are used, rollover of counters is synchronized
34
35
- content of the Modbus Status page is updated in the background (fetch API), javascript alert is shown if connection is lost
35
36
* optimized TCP socket management (web interface and Modbus TCP):
36
37
- gateway always listens for new web and Modbus TCP connections
@@ -57,6 +58,10 @@ Change settings of your Arduino-based Modbus RTU to Modbus TCP/UDP gateway via w
57
58
58
59
**Reboot**.
59
60
61
+
**EEPROM Health**. Keeps track of EEPROM write cycles (persistent, never cleared during factory resets)
62
+
63
+
**Ethernet Sockets**. Max number of usable sockets. See Limitations bellow. One socket is reserved for Modbus UDP, remaining sockets are shared between Modbus TCP and WebUI.
64
+
60
65
**Generate New MAC**. Generate new MAC address. First 3 bytes are fixed 90:A2:DA, remaining 3 bytes are true random.
@@ -73,7 +78,7 @@ Change settings of your Arduino-based Modbus RTU to Modbus TCP/UDP gateway via w
73
78
74
79
**Requests Queue**. Monitors internal request queue (buffer). The limits for bytes and for the number of requests stored in the queue can be configured in advanced settings.
75
80
76
-
**Modbus Statistics**. Counters for various errors. Counters are periodically saved to EEPROM. Insigned longs are used, rollover of counters is synchronized:
81
+
**Modbus Statistics**.
77
82
***Slave Responded**. Slave responded with a valid Modbus RTU response within response timeout.
78
83
***Slave Responded with Error (Codes 1~8)**. Slave responded, but with an error. For the list of error codes see https://en.wikipedia.org/wiki/Modbus#Exception_responses.
79
84
***Gateway Overloaded (Code 10)**. Request queue is full (either the number of bytes stored or the number of requests stored). Request was dropped and the gateway responded with an error code 10.
@@ -148,14 +153,15 @@ Get the hardware (cheap clones from China are sufficient) and connect together:
148
153
***Arduino Nano, Uno or Mega** (and possibly other). On Mega you have to configure Serial in advanced settings in the sketch.
149
154
***W5100, W5200 or W5500 based Ethernet shield**. The ubiquitous W5100 shield for Uno/Mega is sufficient. If available, I recommend W5500 Ethernet Shield. !!! ENC28J60 will not work !!!
150
155
***TTL to RS485 module**:
151
-
- with hardware automatic flow control (recommended, available on Aliexpress)<br>
152
-
Arduino <-> Module<br>
153
-
Tx1 <-> Tx<br>
154
-
Rx0 <-> Rx
155
-
- with flow controlled by pin (such as MAX485 module)<br>
156
-
Arduino <-> MAX485<br>
157
-
Tx1 <-> DI<br>
158
-
Rx0 <-> RO<br>
156
+
- recommended: TTL to RS485 module with hardware automatic flow control (available on Aliexpress)<br>
157
+
Arduino <-> Module
158
+
Tx1 <-> Tx
159
+
Rx0 <-> Rx<br>
160
+
161
+
- not recommended: MAX485 module with flow controlled by pin (works but is vulnerable to burn outs)<br>
// if (W5100.readSnSR(sock) == SnSR::ESTABLISHED && W5100.readSnDPORT(sock) == myHeader.remPort) { // Check remote port should be enough or check also rem IP?
192
-
if (W5100.readSnSR(sock) == SnSR::ESTABLISHED) { // Check remote port should be enough or check also rem IP?
191
+
if (W5100.readSnSR(sock) == SnSR::ESTABLISHED && W5100.readSnDPORT(sock) == myHeader.remPort) { // Check remote port should be enough or check also rem IP?
193
192
if (localConfig.enableRtuOverTcp) client.write(PDU, pduLength);
194
193
else {
195
194
client.write(MBAP, 6);
196
195
client.write(PDU, pduLength - 2); //send without CRC
197
196
}
198
197
#ifdef ENABLE_EXTRA_DIAG
199
-
ethTxCount += pduLength;
200
-
if (!localConfig.enableRtuOverTcp) ethTxCount += 4;
198
+
ethCount[DATA_TX] += pduLength;
199
+
if (!localConfig.enableRtuOverTcp) ethCount[DATA_TX] += 4;
201
200
#endif/* ENABLE_EXTRA_DIAG */
202
201
} // TODO TCP Connection Error
203
-
} // else SCAN_REQUEST (no ethTxCount, but yes delete request)
202
+
} // else SCAN_REQUEST (no ethCount[DATA_TX], but yes delete request)
0 commit comments