regulator: TPS6287X: Use min/max uV to get VRANGE
Changing voltage might ignore slew rate and cause a current surge.
With current implementation the driver will get the regulator to change
the voltage range used during run time. According to communication I
have had with Texas Instruments, this is not intended, since the
Dynamic Voltage Scaling in the hardware is only designed to work
within a voltage range. The current implementation will therefore
ignore the slew rate that is defined in devicetree when the voltage
range is changed during use.
The current implementation will always select a voltage in the most
accurate range that can reach that voltage even though multiple ranges
are able to reach that voltage. There are 4 Voltage ranges with the
following reach:
0b00: 0.4-0.71875V (1.25mV step size)
0b01: 0.4-1.0375V (2.5mV)
0b10: 0.4-1.675V (5mV)
0b11: 0.8-3.3V (10mV)
This in practice means that a change from below to above 0.71875V will
use the smallest range(0b00) for the values below and the second
smallest range(0b01) for the voltages above (Up to 1.675V). I have
timed how long it takes to go from below 0.71875V to above. The
increase was 100mV which, with the slew rate set to 1250µV/µs. This
in theory should take 80µs to do. With the current implementation, it
takes 10µs on my hardware. Doing the same test with the slew rate set
to 5000µV/µs, which should take 20µs, also only takes 10µs to do on
my hardware. Not only is this not in line with the technical
specification for the regulator. It also causes a current surge. Which
when calculating the output current, as described in the technical
specification, compared to what I could observe on my hardware the real
output is ~1A higher (~1.2A) than what I calculated it to be(~0.2A).
I tested also transitioning from a bigger to a smaller range, and the
results were the same.
Instead, let's limit the voltage range to a single one, which is in
line with the intended use of the regulator. This is done by looking
up the minimum and maximum requested voltage specified in devicetree.
Signed-off-by: Jonas Andreasson <jonas.andreasson@axis.com>
Link: https://patch.msgid.link/20250121-tps-fix-v2-1-50cc4d0f1635@axis.com
Signed-off-by: Mark Brown <broonie@kernel.org>1 parent 367a820 commit 3028583
1 file changed
+57
-0
lines changed| Original file line number | Diff line number | Diff line change | |
|---|---|---|---|
| |||
44 | 44 | | |
45 | 45 | | |
46 | 46 | | |
| 47 | + | |
| 48 | + | |
| 49 | + | |
| 50 | + | |
47 | 51 | | |
48 | 52 | | |
49 | 53 | | |
50 | 54 | | |
| 55 | + | |
| 56 | + | |
| 57 | + | |
| 58 | + | |
| 59 | + | |
| 60 | + | |
| 61 | + | |
| 62 | + | |
| 63 | + | |
| 64 | + | |
| 65 | + | |
| 66 | + | |
| 67 | + | |
| 68 | + | |
| 69 | + | |
| 70 | + | |
| 71 | + | |
| 72 | + | |
| 73 | + | |
| 74 | + | |
| 75 | + | |
51 | 76 | | |
52 | 77 | | |
53 | 78 | | |
| |||
91 | 116 | | |
92 | 117 | | |
93 | 118 | | |
| 119 | + | |
| 120 | + | |
| 121 | + | |
| 122 | + | |
| 123 | + | |
| 124 | + | |
| 125 | + | |
| 126 | + | |
| 127 | + | |
| 128 | + | |
| 129 | + | |
| 130 | + | |
| 131 | + | |
| 132 | + | |
| 133 | + | |
| 134 | + | |
| 135 | + | |
| 136 | + | |
| 137 | + | |
| 138 | + | |
| 139 | + | |
| 140 | + | |
94 | 141 | | |
95 | 142 | | |
96 | 143 | | |
| |||
100 | 147 | | |
101 | 148 | | |
102 | 149 | | |
| 150 | + | |
103 | 151 | | |
104 | 152 | | |
105 | 153 | | |
| |||
130 | 178 | | |
131 | 179 | | |
132 | 180 | | |
| 181 | + | |
133 | 182 | | |
134 | 183 | | |
| 184 | + | |
| 185 | + | |
| 186 | + | |
| 187 | + | |
| 188 | + | |
135 | 189 | | |
136 | 190 | | |
137 | 191 | | |
| |||
143 | 197 | | |
144 | 198 | | |
145 | 199 | | |
| 200 | + | |
| 201 | + | |
146 | 202 | | |
147 | 203 | | |
148 | 204 | | |
149 | 205 | | |
150 | 206 | | |
151 | 207 | | |
| 208 | + | |
152 | 209 | | |
153 | 210 | | |
154 | 211 | | |
| |||
0 commit comments